HiFill™ Test HiCynth™ Medium
Media Fill Validation Kit#4fa25a
Composition**
| Ingredients | Gms / Litre |
|---|---|
| HiCynth peptone No. 1* | 17.000 |
| HiCynth peptone No. 5* | 3.000 |
| Sodium chloride | 5.000 |
| Dipotassium phosphate | 2.500 |
| Dextrose | 2.500 |
| MFT indicator | 0.100 |
| Final pH (at 25°C) | 7.30 ± 0.2 |
**Formula adjusted, standardized to suit performance parameters
Directions
Sterile powder can be used directly for the evaluation of sterility in manufacturing process. For sterile liquid medium aseptically add 30.10 grams in 1000 ml sterile distilled / purified water. DO NOT AUTOCLAVE Dispense aseptically in sterile tubes or flasks as desired.
Note: If any fibres are observed in the solution it is recommended to filter the solution through 022 micron filter to eliminate any possibility of presence of fibres.
Principle And Interpretation
Soyabean Casein Digest Medium is recommended by various pharmacopoeia as sterility testing medium (1,2,3,4,5). This medium is prepared by completely replacing animal and vegetable based peptone with chemically defined peptones. HiCynth™ peptone No.1 and HiCynth™ peptone No. 5 in the medium provides nitrogeneous and carbonaceous compounds, long chain amino acids, vitamins and other essential nutrients . Sodium chloride maintains the osmotic balance. Phosphate buffers the medium. Dextrose serves as an energy source. In this line the HiFill™ Test Medium with the addition of MFT indicator, helps to verify the microbiological growth in aseptic production process. MFT Indicator is the medium is utilized by all microorganisms and the microbial contamination is indicated by colour change from light yellow to maroon-red. It is an easier method for detection of contamination with no time consumption.
Quality Control
Appearance
Cream to yellow homogeneous free flowing powder
Colour and Clarity of prepared medium
Yellow coloured clear solution
Reaction
Reaction of 3.00% w/v aqueous solution at 25°C. pH : 7.30±0.20
pH
7.10-7.50
Sterility Testing
No growth is observed after 14 days for Bacteria at 30-35°C and for Fungi at 20-25°C.
Growth Promotion
Cultural characteristics observed after an incubation at 30-35°C for <= 3days for Bacterial and at 20-25°C for <= 5days for Fungal(* under anaerobic condition).
Sterility Testing + Validation
| Organism (ATCC) | Inoculum (CFU) | Growth |
|---|---|---|
| Staphylococcus aureus ATCC 6538 | 50-100 | luxuriant w/ red to maroon colour |
| Staphylococcus aureus ATCC 25923 | 50-100 | luxuriant w/ red to maroon colour |
| Escherichia coli ATCC 8739 | 50-100 | luxuriant w/ red to maroon colour |
| Escherichia coli ATCC 25922 | 50-100 | luxuriant w/ red to maroon colour |
| Pseudomonas aeruginosa ATCC 9027 | 50-100 | luxuriant w/ red to maroon colour |
| Pseudomonas aeruginosa ATCC 27853 | 50-100 | luxuriant w/ red to maroon colour |
| Bacillus subtilis ATCC 6633 | 50-100 | luxuriant w/ red to maroon colour |
| Micrococcus luteus ATCC 9341 | 50-100 | luxuriant w/ red to maroon colour |
| Salmonella Typhimurium ATCC 14028 | 50-100 | luxuriant w/ red to maroon colour |
| Salmonella Abony NCTC 6017 | 50-100 | luxuriant w/ red to maroon colour |
| Streptococcus pneumoniae ATCC 6305 | 50-100 | luxuriant w/ red to maroon colour |
| Candida albicans ATCC 10231 | 50-100 | luxuriant w/ red to maroon colour |
| Candida albicans ATCC 2091 | 50-100 | luxuriant w/ red to maroon colour |
| *Clostridium perfringens ATCC 12924 | 50-100 | luxuriant w/ red to maroon colour |
Storage and Shelf Life
Store between 10-30°C in a tightly closed container and the prepared medium at 2-8°C. Use before expiry date on the label. On opening, product should be properly stored dry, after tightly capping the bottle inorder to prevent lump formation due to the hygroscopic nature of the product. Improper storage of the product may lead to lump formation. Store in dry ventilated area protected from extremes of temperature and sources of ignition Seal the container tightly after use. Use before expiry date on the label.
Product performance is best if used within stated expiry period.
Disposal
User must ensure safe disposal by autoclaving and/or incineration of used or unusable preparations of this product. Follow established laboratory procedures in disposing of infectious materials and material that comes into contact with clinical sample must be decontaminated and disposed of in accordance with current laboratory techniques (6,7).
| Product Name | HiFill™ Test HiCynth™ Medium |
|---|---|
| SKU | MCD2018G |
| Product Type | HiCynth™ |
| Physical Form | Sterile Powder |
| Origin | Chemically defined (HiCynth™) |
| Packaging type | HDPE |
| References | To be added |
| Customized Product Available | No |