CellIx® CO₂ Incubator, 80L
CO₂ incubators provide an optimal cell growth environment by maintaining a humidified atmosphere with temperature and carbon dioxide control. These conditions not only promote cell growth, but also the growth of microbes like bacteria, yeast, molds and other fungi. The contamination-reducing features of CellIx® provides optimal cell growth, valuable contamination control technologies, and advanced design for highly critical cell culture applications.
- Inner mirror finishes and new shape with Pre- filter and perforated shelf without dry heat AND UV sterilization
- Optional: HEPA Filter as per demand, CO₂ regulator
- Inner dim: 520 mm X 390 mm X 490 mm
HEPA Filters
Contamination control and elimination have been a major concern in cell culture laboratories. The in-built HEPA filters in CellIx® continuously filter the chamber air volume. The HEPA filter traps the particulate air borne contaminants, ensures the air inside the chamber remains clean and reduces cross contamination. Our HEPA continuously filters the entire chamber volume every 60 seconds and provides ISO Class 5 (Class 100) air quality conditions within 5 minutes of door opening.
Note: The Fan-less design model will have in-line air filters of 0.22 μm.
Dual Sterilization Modes
While you can manually clean the insides of the CO₂ incubator, this incubator is also equipped with optional dual sterilization method. CellIx® offers dual sterilization modes: a 140°C/180°C dry air sterilization cycle of 10 hours and sterilization by UV method.
The dry heat sterilization is usually chosen over the other methods, since it eliminates mycoplasma, fungi, yeasts, spores and molds. Our dry heat Sterilization sustains 120 cycles at the given temperature.
Easy to Use
You can activate the sterilization cycle with just a touch of a button.
Safe
Heating is automatically cut by safety device when temperature control fails or there is excessive heating over set point.
Effective
All 6 sides of the chamber are covered with heating wires which bring about uniform heating and provides fast heat- up & temperature recovery. Three parts of heating section are controlled and calibrated individually by 3 temperature sensors.
Incubator sterilization can be performed with a 4W UV lamp. The UV light doesn't reach the samples and sterilization can be performed during operation. UV sterilization causes an antimicrobial effect by the damage it causes to a microorganism's DNA when nucleotides absorb high energy photons. This can make UV sterilization an effective solution to reduce contamination.
Contamination Control & Elimination
CellIx® is optionally available with copper oxide chamber instead of the traditional stainless steel. Copper has natural bactericidal & fungicidal properties.
Product Name | CellIx® CO₂ Incubator, 80L |
---|---|
SKU | AI005 |
Application/ Industry | Hospitals, Lab, Pharmaceutical |
Temperature Range | Ambient (+5 to +60) |
Dimension (mm) | 520 x 390 x 490 |
Net weight (kg) | 38 |
Customized Product Available | No |
Specifications
Volume (L) | 80 |
---|---|
Decontamination | AI005UV, AI005HS |
Temperature (°C) Range | Ambient (+5 to +60) |
Temperature (°C) Accuracy | ± 0.1°C (37°C) |
Temperature (°C) Resolution | 0.1°C |
Temperature (°C) Control | Digital PID |
CO2 Range | 0% ~ 20% |
CO2 Accuracy | ± 0.1% (5% CO2) |
CO2 Resolution | 0.1% |
CO2 Sensor | IR C02 Sensor / Thermal conductivity |
CO2 Control | Microprocessor |
CO2 Inlet pressure range | 4.5 psi or 0.3 bar |
Display | LED Display, 1. Alpha numeric message for HEPA filter replacement 2. Access code to lock the parameters |
Operating panel | Individual 3 Channel Touch Button |
Jacket type | Dry Wall Type (6 sides heat) |
Chamber material | Stainless Steel (304) / (316) |
Number of shelves | 02 |
Chamber dimensions (mm) | 320 x 350 x 375 |
Overall dimensions (mm) | 420 x 460 x 570 |
Weight (kg) | 38 |
Common accessories
Chamber capacity: HEPA filters and shelves | AI005-1NO |
---|---|
Dry heat sterilization unit 125°C hot air sterilization | AI005A-1NO |
Copper oxide cavity | AI005B-1NO |
Glass door (Six regions) | AI005C-1NO |
Roller base Table for AI005, Height: 20cm from bottom | AI005D-1NO |
Stacking kit | AI005E-1NO |
Hole for auxiliary monitoring, Dia: 25mm Located on left side | AI05.06A-1NO |
UV Sterilization unit, 4W UV lamp | AI05.06B-1NO |
Oxygen Controller | AI05.06C-1NO |
CO2 Gas Regulator | AI05.06D-1NO |
Humidity Pan (3L) | AI05.06E-1NO |
CO2 Cylinder 10-50 Kg | AI05.06F-1NO |
Dry Heat Sterilization (AI005HS): Maximum 180°C (Note: No need to remove IR CO₂ sensor / Thermal Conductivity)
UV Sterilization (AI005UV): 4W UV is placed on the chamber ceiling. The UV light cannot reach the sample and sterilization is operated during culturing.
Split Door (AI005SD): 6 Split Door for 180L & 5 Split Door for 80 L, for lower Gas Consumption & lower Heat loss